RDBU| Repositório Digital da Biblioteca da Unisinos

Análise comparativa de simulação de ventilação em contexto urbano com coeficientes de pressão tabelados e oriundos de CFD

Show simple item record

metadataTrad.dc.contributor.author Ribeiro, Mateus Fonseca;
metadataTrad.dc.contributor.authorLattes http://lattes.cnpq.br/3952816901874573;
metadataTrad.dc.contributor.advisor Oliveira, Maria Fernanda de;
metadataTrad.dc.contributor.advisorLattes http://lattes.cnpq.br/1555729873996754;
metadataTrad.dc.publisher Universidade do Vale do Rio dos Sinos;
metadataTrad.dc.publisher.initials Unisinos;
metadataTrad.dc.publisher.country Brasil;
metadataTrad.dc.publisher.department Escola Politécnica;
metadataTrad.dc.language pt_BR;
metadataTrad.dc.title Análise comparativa de simulação de ventilação em contexto urbano com coeficientes de pressão tabelados e oriundos de CFD;
metadataTrad.dc.description.resumo A preocupação mundial com a finitude dos recursos naturais é um alerta para a necessidade da otimização do consumo desses recursos no mercado da construção civil. O conforto térmico é um fator relevante na busca por edificações mais sustentáveis, visto que os sistemas de climatização são grandes responsáveis pelo alto consumo energético de edificações. A partir da ventilação natural, se corretamente planejada, é possível climatizar edificações durante boa parte do tempo, em diversas regiões climáticas do Brasil. O uso das simulações computacionais auxilia neste processo no qual se deve levar em consideração o contexto ao qual a edificação a ser analisada está inserida. O objetivo desta dissertação é investigar a influência dos coeficientes de pressão na ventilação interna de uma habitação unifamiliar dentro de um contexto urbano hipotético na cidade de Porto Alegre. Dessa forma, tem-se os coeficientes de pressão como um componente relevante da equação para a avaliação da ventilação natural na simulação computacional. Nesta dissertação, buscou-se aplicar um método de simulação em fluidodinâmica computacional para a obtenção de coeficientes de pressão próprios ao contexto criado e comparados aos coeficientes de pressão tabelados, amplamente utilizados, fornecidos pela AIVC. Para a análise comparativa, foi modelada uma unidade habitacional unifamiliar no software de simulação energética DesignBuilder e simulada com coeficientes de pressão obtidos pela simulação CFD e os encontrados no banco de dados AIVC. Os resultados encontrados indicaram níveis superestimados de renovações de ar para os coeficientes de pressão AIVC levando em consideração o contexto hipotético avaliado. Foram registradas diferenças de temperatura operativa horária que chegam a 1,05º C entre os dois modelos.;
metadataTrad.dc.description.abstract The limited availability of natural resources raised a global awareness to the necessity of optimizing the consumption of these resources in the civil construction. Thermal comfort is an important factor in the pursuit of making sustainable buildings since active conditioning systems are quite responsible for the high energy consumption in buildings. A properly designed natural ventilation is capable to provide thermal comfort during most of the time in the many climatic regions of Brazil. The use of thermal simulations assists the design process of natural ventilation, in which the context where the building is inserted must be considered. The aim of this research is to evaluate the influence of the pressure coefficients in the natural ventilation of an isolated residential building located in a specific context created in the city of Porto Alegre. The pressure coefficients are relevant components of the equations that evaluate the natural ventilation in the computer simulation. The method applied in this research relied on a Computational Fluid Dynamics simulation to obtain pressure coefficients specific to the context created and compared to the widely used AIVC pressure coefficients. In order to analyze the impact of the different pressure coefficients, the housing unit was modeled in an energy simulation software. Hence, it was simulated with the CFD pressure coefficients and the AIVC database pressure coefficients. The results found indicated overpredicted levels of air exchange for the AIVC pressure coefficients, considering the context evaluated. Differences in hourly operative temperature reached 1.05º C between the two models.;
metadataTrad.dc.subject Coeficientes de pressão; Ventilação natural; CFD; Simulação computacional; Pressure coefficients; Natural ventilation; Themal simulation;
metadataTrad.dc.subject.cnpq ACCNPQ::Ciências Sociais Aplicadas::Arquitetura e Urbanismo;
metadataTrad.dc.type Dissertação;
metadataTrad.dc.date.issued 2022-03-04;
metadataTrad.dc.description.sponsorship Nenhuma;
metadataTrad.dc.rights openAccess;
metadataTrad.dc.identifier.uri http://www.repositorio.jesuita.org.br/handle/UNISINOS/11390;
metadataTrad.dc.publisher.program Programa de Pós-Graduação em Arquitetura e Urbanismo;


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search

Advanced Search

Browse

My Account

Statistics